Guangzhou Kingrise Enterprises Co., Ltd.

Meter Test Expert

Home ProductsThree Phase Meter Test Bench

Accuracy 0.05 Three Phase Meter Test Bench 48 Position For CT / PT LTPT 120A

Certification
China Guangzhou Kingrise Enterprises Co., Ltd. certification
China Guangzhou Kingrise Enterprises Co., Ltd. certification
Product is good, service is good. Nice company to do business with.

—— Carlos

Glad to meet you, you are a professional manufacturer. Hope we do more and more business in the coming future.

—— Ламбринаки М.А.

I'm Online Chat Now

Accuracy 0.05 Three Phase Meter Test Bench 48 Position For CT / PT LTPT 120A

Accuracy 0.05 Three Phase Meter Test Bench 48 Position For CT / PT LTPT 120A
Accuracy 0.05 Three Phase Meter Test Bench 48 Position For CT / PT LTPT 120A

Large Image :  Accuracy 0.05 Three Phase Meter Test Bench 48 Position For CT / PT LTPT 120A

Product Details:
Place of Origin: China
Brand Name: KRE
Certification: ISO9000
Model Number: KE8301F
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Packaging Details: Plywood case
Delivery Time: 30 days
Payment Terms: Western Union, L/C, T/T, D/P, D/A, MoneyGram
Supply Ability: 50 pieces per month
Detailed Product Description
Current Range: 1mA - 120A Warranty: 12 Months
Accuracy: 0.05 Structure Type: Separated Type
Voltage Output: 24V - 300V Meter Test Type: CT/PT Meter, 3P3W, 3P4W
Meter Position: 48 Standard: IEC 60736
High Light:

three phase energy meter test bench

,

electric meter testing equipment

,

48 Position Meter Test Bench

 

KE8301F  Three Phase Meter Test Bench

 

Accuracy : 0.05 , it is used for the test of three phase CT/PT meter with a accuracy class below 0.2, and can test single phase meter if adding an isolation voltage transformer.

 

 

Features:

  1. Meter positions can be chosen from 3 - 48
  2. Integrated / separated aluminum alloy structure, light and reliable, flexible choices
  3. Auto protection of short circuit of voltage, open circuit of current, and overload.
  4. Test of neutral current (optional)
  5. Full automatic, semi automatic and manual operation available
  6. Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters( optional)
  7. Test of tilt impact (optional)
  8. Forward and reverse active energy / forward and reverse reactive energy error test
  9. Creeping and starting test
  10. Standard deviation, 24 hour variation test
  11. Timing error test
  12. Influencing quantity test of voltage, frequency, harmonic
  13. Calibration and verification of constant
  14. Register indicating value, register combination error test
  15. Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms

 

 

Main Specification:

 

  KE8301-6 KE8301-12 KE8301-24 KE8301-48
Number of meter position 6 12 24 48
Accuracy ± 0.05%
Voltage output
Output range (P-N) 3×(24V – 300V)
Output power of voltage 3×100VA 3×250VA 3×500VA 3×1000VA
Resolution Better than ± 0.01%
Stability Better than ± 0.02% / 150s
Load regulation rate Better than ± 0.01%
Distortion factor Better than ± 0.3% (linear resistance load)
Harmonics output 2nd -21st free programmable
Current output
Output range 1mA – 120A (or customized,Max. 230A) 3×(1mA – 120A)
Output power of current 3×150VA 3×350VA 3×750VA 3×1500VA
Resolution Better than ± 0.01%
Stability Better than ± 0.02% / 150s
Load regulation rate Better than ± 0.01%
Distortion factor Better than ± 0.3% (linear resistance load)
Harmonics output 2nd -21st free programmable
Phase output
Output range 0 -- 360°
Resolution ± 0.01°
Frequency output
Output range 45Hz – 65Hz
Resolution ± 0.01Hz
Operation conditions
Power supply 3×220/380V±10% ,50/60Hz±2Hz
Temperature -10°C -- +40°C
Humidity 35% -- 85%RH

 

 