Guangzhou Kingrise Enterprises Co., Ltd.

Meter Test Expert

Home ProductsEnergy Meter Testing Equipment

10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit

Certification
China Guangzhou Kingrise Enterprises Co., Ltd. certification
China Guangzhou Kingrise Enterprises Co., Ltd. certification
Product is good, service is good. Nice company to do business with.

—— Carlos

Glad to meet you, you are a professional manufacturer. Hope we do more and more business in the coming future.

—— Ламбринаки М.А.

I'm Online Chat Now

10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit

10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit
10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit

Large Image :  10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit

Product Details:
Place of Origin: China
Brand Name: KRE
Certification: ISO9000
Model Number: KE9806
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Packaging Details: Plywood case
Delivery Time: 30 days
Payment Terms: Western Union, L/C, T/T, D/P, D/A, MoneyGram
Supply Ability: 50 pieces per month
Detailed Product Description
Current Range: 0.01 - 1000A Warranty: 12 Months
Accuracy: 0.05 Voltage Output: 0V - 10kV
Test Object: Ring Main Unit (RMU) Standard: IEC
Phase: Three
High Light:

energy meter test bench

,

meter test system

,

10kv Energy Meter Testing Equipment

10kv High Voltage RMU Test Equipment for Ring Main Unit high grade 0.05 1000A

 

KE9806 10kv High Voltage RMU Test Equipment

 

KE9801 can simulate user's on-site environment for testing and inspection. It is mainly used to calibrate the error of ring main unit and verify whether the product's functions conform to national standards and industry standards. 

 

 

Basic functions:

 

  1. Overall error calibration and metrological verification of RMUs.
  2. 10kV measurement box (cabinet) overall error calibration and measurement verification.
  3. Error calibration and metrological verification of distribution line loss acquisition module.
  4. Overall error calibration and metrological verification of weak output combined transformer and weak input energy meter.
  5. Calibration of electromagnetic transformer, electronic transformer, multi-ratio transformer.

Test items:

 

  1. Basic error, creeping test, starting test, time and date, constant check, standard deviation, 485 communication, voltage, current, power factor, frequency error detection.
  2. Zero-sequence voltage, zero-sequence current, active power, and reactive power error detection.
  3. Harmonic influence error detection.
  4. Telemetry detection: current, voltage, power due to numerical detection, increase the amount of comparison, the program can set the load point, verification time and so on.
  5. Remote detection: switch on and off test
  6. Remote signal detection: cooperates with remote control detection to test FTU (DTU) communication and other functions.
  7. Fault current detection: add overload current to the switch that sets the current value, and test whether the switch responds to overcurrent alarm.
  8. Protection testing: first overcurrent detection and second overcurrent detection.
  9. The power source can simulate the zero-sequence voltage and current and output them.
  10. Test of transformer angle difference and ratio error(optional function).
  11. Simulated short-circuit ground fault test, typical small-current single-phase metal grounding, low-impedance single-phase grounded, high impedance single-phase ground wave output (optional function).
  12. Automatic generation of test reports.

 

Main Specification:

 

Accuracy

 

Overall active energy

 

± 0.05%

Overall reactive energy

 

± 0.05%

Voltage transformer

 

± 0.02%

Current transformer

 

± 0.01% (50mA – 1000A)

Three phase reference meter

 

± 0.05%

Voltage output

 

Rated value(P-N)

 

57.7V,11.54kV

Rated value(P-P)

 

20kV

Output power (per phase)

 

600VA

Adjust range

 

0%~120%

Resolution

 

10%,1%,0.1%,0.01% and stepless regulation

Load characteristic

 

Resistive, capacitive, inductive
Rated output value of voltage transformer 5.77kV/57.7V,11.54kV/57.7V

Current output

 

Output range (per phase)

 

10mA – 1000A

Output power (per phase)

 

2000VA

Adjust range

 

0%~120%
Resolution 10%,1%,0.1%,0.01% and stepless regulation

Load characteristic

 

 

Phase output

 

Output range

 

0 -- 360°
Resolution 10°,1°,0.1°,0.01° and stepless regulation

Frequency output

 

Output range

 

45Hz – 65Hz
Resolution 10Hz,1Hz,0.1Hz,0.01Hz and stepless regulation

Inner insulation

 

Between high voltage and low voltage 30kV PF voltage per minute

Operating condition

 

Power supply

 

3×220/380V±10%,50/60Hz±2Hz

Max power consumption

 

10kVA

Environment temperature

 

-10°C -- +40°C

Environment humidity

 

35% -- 85%

Other

 

Product dimensions

Separated type:
lower side 575mm ×1000mm × 2276mm
higher side 1415mm x 1518mm x 2276mm

 

integral mobile type:
1420mm x 1000mm x 1700mm

 

Weight

Separated type:
lower side 500kg
higher side 450kg


Integral mobile type:
850kg

 

 

 

10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit 0

 