| Product Details: 
 Payment & Shipping Terms: 
 | 
| Accuracy: | 0.05 | Material: | Aluminium Alloy | 
|---|---|---|---|
| Meter Positions: | 6-96 | Warranty: | 12 Months | 
| Current Output: | 1mA - 120A | Voltage Output: | 24V - 300V | 
| Highlight: | electric meter calibration equipment,test and measurement equipment,24 position electric meter calibration equipment | ||
KE8101 single phase meter test equipment is used for the test of various single phase electric and mechanical meter, multi-function meter, PLC meter, multi-rate meter and prepayment meter.
Features:
• Integrated / Separated aluminum alloy structure, light and reliable, flexible choices
• The number of meter positions can be chosen from 3-96
• can test up to 96 meters at the same time
• Perfect alarming protective function, auto protection of the short circuit of voltage, the open circuit of current, and overload.
• Full automatic, semi automatic and manual operation available
• Supporting bar code input, which increase the efficiency of input
• Simultaneous test of the energy meters with same specification, different constants and different classes.
• Auto mark locking increases the efficiency of test
• Forward and reverse active energy / forward and reverse reactive energy error test
• Creeping and starting test
• Standard deviation, 24 hour variation test
• Influencing quantity test of voltage, frequency, harmonic of different orders
• Calibration and verification of energy constant
• Powerful computer management system, easy and user-friendly
• Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms
• The test of open circuit for Neutral voltage (optional)
• Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters (optional)
Main Specification:
| KE8101-24 | |
| Number of meter position | 24 | 
| Accuracy | ±0.05% | 
| Voltage output | |
| Output range (P-N) | 24V - 300V | 
| Output power of voltage | 500VA | 
| Resolution | Better than ± 0.01% | 
| Stability | Better than ± 0.02% / 150s | 
| Load regulation rate | Better than ± 0.01% | 
| Distortion factor | Better than ± 0.3% (linear resistance load) | 
| Harmonics output | 2nd -21st free programmable | 
| Current output | |
| Output range | 1mA - 120A | 
| Output power of current | 750VA | 
| Resolution | Better than ± 0.01% | 
| Stability | Better than ± 0.02% / 150s | 
| Load regulation rate | Better than ± 0.01% | 
| Distortion factor | Better than ± 0.3% (linear resistance load) | 
| Harmonics output | 2nd -21st free programmable | 
| Phase output | |
| Output range | 0 -- 360° | 
| Resolution | ± 0.01° | 
| Frequency | |
| Output range | 45Hz - 65Hz | 
| Resolution | ± 0.01Hz | 
| Operation condition | |
| Power supply | 220V±10%,50/60Hz±2Hz | 
| Temperature | -10°C -- +40°C | 
| Humidity | 35% -- 85%RH | 

Tel: 86-20-6222-0193
Fax: 86-20-6222-0182