| Product Details: 
 Payment & Shipping Terms: 
 | 
| Phase: | Three | Frequency: | 45 - 65Hz | 
|---|---|---|---|
| Usage: | Energy Meter Calibration, Lab Research | Current Range: | 1mA - 120A | 
| Warranty: | 12 Months | Accuracy: | 0.01 | 
| Structure Type: | Separated Type | Meter Position: | 10 | 
| Highlight: | test and measurement equipment,electrical lab testing equipment,0.01 Accuracy Energy Meter Calibration Equipment | ||
KE8300F Three Phase Electric Meter Testing Equipment
Accuracy : 0.01 , Used for the test of standard meter and mounted meter with a accuracy class below 0.05, Number of meter position : 3-12
Features:
· High accuracy: 0.01%
· Integrated / separated aluminum alloy structure, light and reliable, flexible choices
· Meter positions can be chosen from 3 - 12
· Auto protection of short circuit of voltage, open circuit of current, and overload.
· Full automatic, semi automatic and manual operation available
· Supporting bar code input, which increase the efficiency of input
· Simultaneous test of the meters with same specification, different constants and different classes.
· Forward and reverse active energy / forward and reverse reactive energy error test
· Creeping and starting test
· Standard deviation, 24 hour variation test
· Timing error test
· Influencing quantity test of voltage, frequency, harmonic
· Calibration and verification of constant
· Register indicating value, register combination error test
· Powerful computer management system, easy and user-friendly
· Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms
Main Specification:
| KE8300F | |
| Number of meter position | 3/6/10 | 
| Accuracy | ±0.01% | 
| Voltage output | |
| Output range (P-N) | 3 x (24V - 300V) | 
| Output power of voltage | 3 x 200VA | 
| Resolution | Better than ± 0.01% | 
| Stability | Better than ± 0.02% / 150s | 
| Load regulation rate | Better than ± 0.01% | 
| Distortion factor | Better than ± 0.3% (linear resistance load) | 
| Harmonics output | 2nd -21st free programmable | 
| Current output | |
| Output range | 3 x (1mA - 120A) | 
| Output power of current | 3 x 300VA | 
| Resolution | Better than ± 0.01% | 
| Stability | Better than ± 0.02% / 150s | 
| Load regulation rate | Better than ± 0.01% | 
| Distortion factor | Better than ± 0.3% (linear resistance load) | 
| Harmonics output | 2nd -21st free programmable | 
| Phase output | |
| Output range | 0 -- 360° | 
| Resolution | ± 0.01° | 
| Frequency | |
| Output range | 45Hz - 65Hz | 
| Resolution | ± 0.01Hz | 
| Operation condition | |
| Power supply | 220V±10%,50/60Hz±2Hz | 
| Temperature | -10°C -- +40°C | 
| Humidity | 35% -- 85%RH | 
Tel: 86-20-6222-0193
Fax: 86-20-6222-0182